Lichtkanal 070
Plasterboard Recessed Trimless

LK-P 070.003 AOB/...

LK-P 070.003 AOB/...

light trunking system (made-to-measure) for recessed mounting with gap into suitable for opal diffuser protruding and Choc light-inserts (LK-CH...), high-quality extruded aluminium profile for fixing into trimless recessed frame, possible mitre cuts for surfaces, wall/ceiling inside, edge outside/inside (cutting cost on request), trimless recessed frame, light-inserts and (necessary) accessories to be ordered separately, opal flush acrylic glass diffuser made from PMMA with tool-free snap-in technology, quick-mounting in trimless mounting frame via turning bolts

Note: For luminaires with only "1 light-insert" add "+5 mm" for end covers. Required space on the end faces is 10 mm each. The linear thermal expansion of the aluminium profile is about 0.3 mm per meter at dT = 10 Kelvin. IP40 only applies in combination with mounted acrylic glass diffuser mounted acrylic glass profile. Pretreat the plaster zone on the luminaire and ceiling with suitable adhesion primer.

Special dimensions: order length of mounting frame = length of empty profile + (2 x 3 mm thickness of end covers) + (2 x 3.5 mm gap) = length of empty profile + 13 mm; ceiling cut-out = (length of mounting frame + 6 mm) x 96 mm

Technical data

Norms:CE,RoHS
Type of protection:IP40
Weight:1.94 kg
Colour: silver anodised, black, white

Article overview

Article no.EANNameProduct picture
6686844043544803542LK-P 070.003 AOB/... SI-ANOD
6686854043544803559LK-P 070.003 AOB/... BK
6686864043544803566LK-P 070.003 AOB/... WH

Accessories

LK-Z 070 AOB-K-001

concealing unit for acrylic glass flush

LK-Z 070 AOB/...

opal acrylic glass flush as replacement (length made-to-measure)

LK-Z 070 APB/...

prismatic acrylic glass flush as replacement (length made-to-measure)

LK-Z 070 BA/...

blind cover (length made-to-measure)

LK-Z 070 SENSOR/OR

Organic Response sensor (DALI PS3) for Lichtkanal 070

LK-Z 070.001

end covers (2 pieces)

LK-Z 070.003.00 TRI/...

mounting frame trimless for plasterboard (length made-to-measure)

LK-Z 070.003.90 TRI

mounting frame trimless 90° corner for plasterboard

LK-Z 070.100

connection kit with earthing

LK-Z 070.102.90

connector kit for corners

LK-Z 070.110

earthing kit for sectional form parts (mitres)

STRL-LK-Z 070-060.102.00

connector kit linear

Lighting inserts

NameSystem powerlight-insert
power stage 210.3 WLK-L 070.10830.0705.1/DALI3000 K 1670 lm 705 mm
power stage 210.3 WLK-L 070.10840.0705.1/DALI4000 K 1770 lm 705 mm
power stage 212.4 WLK-L 070.10830.0845.1/DALI3000 K 2000 lm 845 mm
power stage 212.4 WLK-L 070.10840.0845.1/DALI4000 K 2120 lm 845 mm
power stage 214.5 WLK-L 070.10830.0985.1/DALI3000 K 2330 lm 985 mm
power stage 214.5 WLK-L 070.10840.0985.1/DALI4000 K 2470 lm 985 mm
power stage 216.5 WLK-L 070.10830.1125.1/DALI3000 K 2670 lm 1125 mm
power stage 216.5 WLK-L 070.10840.1125.1/DALI4000 K 2830 lm 1125 mm
power stage 220.7 WLK-L 070.10830.1405.1/DALI3000 K 3330 lm 1405 mm
power stage 220.7 WLK-L 070.10840.1405.1/DALI4000 K 3530 lm 1405 mm
power stage 224.8 WLK-L 070.10830.1685.1/DALI3000 K 4000 lm 1685 mm
power stage 224.8 WLK-L 070.10840.1685.1/DALI4000 K 4240 lm 1685 mm
power stage 233.1 WLK-L 070.10830.2245.1/DALI3000 K 5330 lm 2245 mm
power stage 233.1 WLK-L 070.10840.2245.1/DALI4000 K 5650 lm 2245 mm
power stage 2 & emergency light16.5 WLK-L 070.10830.1125.1/DALI/NO3000 K 2670 lm 1125 mm
power stage 2 & emergency light16.5 WLK-L 070.10840.1125.1/DALI/NO4000 K 2830 lm 1125 mm
power stage 2 & emergency light20.7 WLK-L 070.10830.1405.1/DALI/NO3000 K 3330 lm 1405 mm
power stage 2 & emergency light20.7 WLK-L 070.10840.1405.1/DALI/NO4000 K 3530 lm 1405 mm
power stage 2 & emergency light24.8 WLK-L 070.10830.1685.1/DALI/NO3000 K 4000 lm 1685 mm
power stage 2 & emergency light24.8 WLK-L 070.10840.1685.1/DALI/NO4000 K 4240 lm 1685 mm
power stage 2 & emergency light33.1 WLK-L 070.10830.2245.1/DALI/NO3000 K 5330 lm 2245 mm
power stage 2 & emergency light33.1 WLK-L 070.10840.2245.1/DALI/NO4000 K 5650 lm 2245 mm
power stage 315.9 WLK-L 070.11830.0705.1/DALI3000 K 2570 lm 705 mm
power stage 315.9 WLK-L 070.11840.0705.1/DALI4000 K 2720 lm 705 mm
power stage 319.1 WLK-L 070.11830.0845.1/DALI3000 K 3080 lm 845 mm
power stage 319.1 WLK-L 070.11840.0845.1/DALI4000 K 3260 lm 845 mm
power stage 322.3 WLK-L 070.11830.0985.1/DALI3000 K 3590 lm 985 mm
power stage 322.3 WLK-L 070.11840.0985.1/DALI4000 K 3800 lm 985 mm
power stage 325.5 WLK-L 070.11830.1125.1/DALI3000 K 4110 lm 1125 mm
power stage 325.5 WLK-L 070.11840.1125.1/DALI4000 K 4350 lm 1125 mm
power stage 331.9 WLK-L 070.11830.1405.1/DALI3000 K 5120 lm 1405 mm
power stage 331.9 WLK-L 070.11840.1405.1/DALI4000 K 5430 lm 1405 mm
power stage 338.3 WLK-L 070.11830.1685.1/DALI3000 K 6150 lm 1685 mm
power stage 338.3 WLK-L 070.11840.1685.1/DALI4000 K 6520 lm 1685 mm
power stage 351.0 WLK-L 070.11830.2245.1/DALI3000 K 8200 lm 2245 mm
power stage 351.0 WLK-L 070.11840.2245.1/DALI4000 K 8690 lm 2245 mm
power stage 3 & emergency light25.5 WLK-L 070.11830.1125.1/DALI/NO3000 K 4110 lm 1125 mm
power stage 3 & emergency light25.5 WLK-L 070.11840.1125.1/DALI/NO4000 K 4350 lm 1125 mm
power stage 3 & emergency light31.9 WLK-L 070.11830.1405.1/DALI/NO3000 K 5120 lm 1405 mm
power stage 3 & emergency light31.9 WLK-L 070.11840.1405.1/DALI/NO4000 K 5430 lm 1405 mm
power stage 3 & emergency light38.3 WLK-L 070.11830.1685.1/DALI/NO3000 K 6150 lm 1685 mm
power stage 3 & emergency light38.3 WLK-L 070.11840.1685.1/DALI/NO4000 K 6520 lm 1685 mm
power stage 3 & emergency light51.0 WLK-L 070.11830.2245.1/DALI/NO3000 K 8200 lm 2245 mm
power stage 3 & emergency light51.0 WLK-L 070.11840.2245.1/DALI/NO4000 K 8690 lm 2245 mm

Downloads

Product information
Revit/BIM
Revit data available on request
Images

Tender text